RBC  7000

RBC4000


Static Frequency Converter

Three Phase Input System with Three Phase Output 10kVA – 300kVA

Red Box International Static Frequency Converters employ high frequency PWM technology (IGBT’s) to achieve a high quality output under all load conditions. The systems are designed with PFC (Power Factor Correction), thereby reducing input current and harmonic distortion.

Red Box International Static Frequency Converters are available in a wide power range and include an output isolation transformer as standard. The design offers flexibility on the input as well as the output, and can be configured for a wide variety of voltages and frequencies. A comprehensive LCD display, control panel and data logger provide detailed and accurate status and control of the system.

The Red Box International RBC series provides flexibility, efficiency and compatibility in applications where high quality wave shape is a critical factor.

 

Standard Features

  • Adjustable Output Frequency
  • Adjustable Output Voltage
  • Sine Wave Output
  • Microprocessor control
  • Modular Design Improving Reliability and Serviceability
  • Data Logger Stores up to 200 Alarms

 

Optional Features

  • High IP Rating (Max IP 54)
  • RS232 Interface
  • Volt Free Contacts
  • Other Voltage / Frequencies
  • Remote Start / Stop
  • Emergency Power Off
  • Battery Backup (UPS)
  • Built in Distribution
  • Output Earth Leakage Detection

 

model specifications

5kVA

10kVA

15kVA

20kVA

30kVA

40kVA

50kVA

100kVA

150kVA

180-300kVA

Output Active Power (kW)

10.00

15.00

20.00

30.00

40.00

50.00

60.00

150.00

180 - 300.00

Apparent Output Power (kVa)

10.00

15.00

20.00

30.00

40.00

50.00

60.00

150.00

180 - 300.00

INPUT:
Number of Phases
3
3
3
3
3
3
3
3
3
Nominal Input Voltage VAC

400

400

400

400

400

400

400

400

400

Voltage Tolerance + / - 10%
Nominal Input Frequency 50Hz (+/-5%)
OUTPUT:
Nominal Output Voltage Vac 190/200/208 or 380/400/415V Three phase
Voltage Adjustment 56-228V / 311-459V
Static Voltage Regulation + / - 1%
Nominal Output Frequency 50 / 60 / 400Hz
Frequency Adjustment

45-65Hz / 360-400Hz

Output Frequency Stability 0.1Hz
Output Wave Shape SINE WAVE
Load Power Factor 0.7 LAG à 0.9 LEAD
Overload (Kva) 121% - 2 mins, 160% - 5 secs

*Other voltages and frequencies available on request.

GENERAL:
Operating Temperature 0-40˚C
Relative Humidity 90% NON-CONDENSING
Altitude MAX 1000M BEFORE DERATING
Protection Level IP21
Colour RAL 7035 (other colours available)
Noise Level <55 – 70 dBA @ 1m (free filed conditions)
System For weight and dimensions of each unit please contact us directly.
STANDARDS:
Safety BS EN 62040-1
EMC BS EN 62040-2
Harmonics BS EN 61000-3-4
System Operation The Power Factor Corrected rectifier converts the single or three phase mains supply into DC, the PWM inverter switches the DC back to AC at the desired frequency and voltage, the output transformer provides Galvanic Isolation which isolates the input and output from each other. The output neutral is bonded to earth for safety.
PROTECTIONS:
Overload Protection The system provides electronic overload protection to protect the system from excessive loading. Standard overloads settings allow for 121% for 2 minutes and 160% for 5 seconds.
Short-Circuit Protection The system provides electronic short circuit protection by combination of IGBT saturation detection and peak current limiting.
Fault Clearance The system has a high fault clearance capability, as a general rule the system can clear a load circuit breaker of typically one third of the output current (C Curve). Designers should bear this in mind when calculating fault discrimination.
Overvoltage Protection The system provides over voltage protection by monitoring input and output voltages electronically and shutting down the system to prevent damage. In addition, surge arrestors are fitted to the input and output for additional protection.
Phase Rotation Detection On three phase input systems, the phase rotation is checked before initialising the rectifier to ensure phase rotation is correct (clockwise).
DIGITAL DISPLAY:
Indicating Lights

Load on inverter
Over temperature
Overload
Inverter off
Rectifier fault

Push buttons

Meter scrolling
Multi-function for LCD menu
Inverter on/off
Buzzer mute

Alarms

Mains failure
Overload short circuit
Inverter fault
Over temperature
Charger fault
Under / over voltage
Power supply fault
Phase rotation incorrect
IGBT saturation

Display Type 4 Line x 20 Character LCD
Metering

Mains Voltage / Hz
Inverter Voltage
Load VA
Load %
Load Current

Other Information

Time and date
Enclosure temperature
Setup information

REMOTE MONITORING/CONNECTIONS
Vault Free Contacts Includes 1 volt free contact for status of the system output. Normally open and normally closed contacts are provided. Alarm relays are energized when in healthy condition and relax into the fault condition. This ensures the contacts indicate a fault condition even when the system is off.
ENCLOSURE:
Enclosure Features

Zintec Sheet Steel
Rear Cable Entry (5-20kVA)
Top Cable Entry (30-300kVA)
Removable Gland / Back Plates
Fitted with castors (5-20kVA)

Other Voltage Frequencies

Other voltages and frequencies available on request (optional extra for 5-20kVA units).

Battery Backup (UPS0

Valve Regulated Lead Acid (VRLA). 10 Year Life at 20˚C. Complies with BS EN60896-2 (optional extra for 5-20kVA units).

Additional Volt Free Contacts

Available for more comprehensive monitoring (optional extra for 5-20kVA units).

Emergency Power off (EPO) Turns off system output and shuts down rectifier (optional extra for 5-20kVA units).
OPTIONAL FEATURES:
Built-In Distortion Single or double pole output circuit breakers can be fitted internally to eliminate the need for an external distribution board. Maximum number of outlets is 10 for single pole and 5 for double pole.
AC Output Earth Leakage Indication

Indicates downstream earth leakage, can be set to 30, 100 or 300mA.

Remote Monitoring (RS232)

The system can be monitored and interrogated remotely using RS232 connection.

Remote Start/Stop

Allows the inverter to be controlled remotely.

High IP Rating Enclosure ratings are available from Standard IP 23 – maximum IP 54.
download specifications sheet

 

 
 
 
 
© 2012 Red Box International - RBC 7000 Frequency Converter
red box international findus sitemap facebooklinkedin