Power Equipment Aircraft Moving Equipment Tools and Solution Boxes Portable Coolers Camera and Inspection Cables and Connectors Load Banks Lithium Batteries
 
eqa
eqa-certificate 2008
eqa-certificate 2004
 
 
 
South Coast business awards finalist
 
red box military
 
red box inspection
 
red box aviation
 
red box automotive
 
red box Marine
 
red box rail
 
Weld and metal craft
 
customer survey
 
subzero climates
 
finance options
 
related aviation companies
 
. I like

400 Hz  Digital Load Banks

 

Red Box provide a range of portable resistive load banks for civil and military aviation. Our 400Hz digital load banks provide a contained, organised and fully controllable load, with the highest quality components.

 
 
product specifications

DISPLAY

  • Easy to read 3-row (2x4 characters + 1x5 characters) bright LED display, adjustable update time and brightness.
  • Auto-scroll option with adjustable page exposition time; auto-return to a default page.
  • LED bar graph showing percent load with respect to user.
  • Definable nominal load current Event and Data recording.
  • Non-volatile memory for long term event and data recording.
  • Event recorder for logging internal diagnostic events and setup changes.
  • Two data recorders, programmable data logs on a periodic basis; automatic daily energy and maximum demand profile log.

 

 

VALUES

  • Nominal voltage range of 0-690V L-L.
  • One communication port RS485, protocol: ASCII, improved MODBUS and DNP 3.0 Level 2.
  • Bright LED display.
  • Standard THD and individual Harmonics to 40 for Voltages and Currents.
  • TDD and K-Factor for Currents.
  • Neutral Current.
  • Voltages and Currents.
  • Unbalance.
  • Energy (Import/Export) – kWh, kVah, kvarh and Demand (Max, Accum, Sliding, Projected).
  • Kw.
  • Kva.
  • Kvar.
  • Energy Registers.
  • Max Demand Registers.
  • Harmonic Measurements- synthesised voltage and current waveforms (via PAS software).

 

     

MEASURES

  • Volts.
  • Amps.
  • Vars.
  • VA.
  • PF.
  • Hz.
  • Phase Rotation.
  • Neutral Current.
  • Voltages and Currents.
  • Unbalance.
  • Max. Demand (Amps, Watts).
  • Min/Max.
   

Seal and product boxes

 
 
 
 
 

400Hz DIGITAL Load Bank 45 KVA-RAB-45 D

   
45 KVA- RAB-45 D
 
model specifications
VOLTAGE [V] 115 / 200 V AC ±10 %
FREQUENCY [Hz] 400 Hz ±5 %
POWER [kW] (cos φ=1) 45 kVA
VARIABLE LOAD STEPS 0 – 45 kVA
COOLING–FORCED [m³/min] 66.15
MEASUREMENT 3 LINE DIGITAL POWER METER WITH USB OUTPUT
NORMS
STANDARDS ISO 6858, DSF 400, ARP 5015
CLASSIFICATION CE marking, DIN, VDE, IEC
ENVIRONMENT
OPERATING TEMPERATURE -10 do + 40 ºC
MAXIMUM ALTITUDE 1000 m (WITHOUT DOWNGRADING), max 2000 m
RELATIVE HUMIDITY 0% – 70% (W.O.CONDENSATION)
NOISE LEVEL <70
DEGREE OF PROTECTION IP 21
DIMENSIONS [ L x B x H mm] 600 X 230 X 630
WEIGHT [kg] 26
PAINTING RAL 29/80081-Tiger / Austria
download specifications sheet
 
 

400Hz Load Bank - Digital  80 KVA- RAB-80 D

   
80 KVA- RAB-80 D
 
model specifications
VOLTAGE [V] 115 / 200 V AC ±10 %
FREQUENCY [Hz] 400 Hz ±5 %
POWER [kW] (cos φ=1) 80 kVA
VARIABLE LOAD STEPS 0 – 80 kVA
COOLING–FORCED [m³/min] 88.20
MEASUREMENT 3 LINE DIGITAL POWER METER WITH USB OUTPUT
NORMS
STANDARDS ISO 6858, DSF 400, ARP 5015
CLASSIFICATION CE marking, DIN, VDE, IEC
ENVIRONMENT
OPERATING TEMPERATURE -10 do + 40 ºC
MAXIMUM ALTITUDE 1000 m (WITHOUT DOWNGRADING), max 2000 m
RELATIVE HUMIDITY 0% – 70% (W.O.CONDENSATION)
NOISE LEVEL <70
DEGREE OF PROTECTION IP 21
DIMENSIONS [ L x B x H mm] 600 X 230 X 630
WEIGHT [kg] 28
PAINTING RAL 29/80081-Tiger / Austria
download specifications sheet
 
 

400 Hz DIGITAL Load Bank 100 KVA-RAB-100 D

   
100 KVA- RAB-100 D
 
model specifications
VOLTAGE [V] 115 / 200 V AC ±10 %
FREQUENCY [Hz] 400 Hz ±5 %
POWER [kW] (cos φ=1) 100 kVA
VARIABLE LOAD STEPS 0 – 100 kVA
COOLING–FORCED [m³/min] 88.20
MEASUREMENT 3 LINE DIGITAL POWER METER WITH USB OUTPUT
NORMS
STANDARDS ISO 6858, DSF 400, ARP 5015
CLASSIFICATION CE marking, DIN, VDE, IEC
ENVIRONMENT
OPERATING TEMPERATURE -10 do + 40 ºC
MAXIMUM ALTITUDE 1000 m (WITHOUT DOWNGRADING), max 2000 m
RELATIVE HUMIDITY 0% – 70% (W.O.CONDENSATION)
NOISE LEVEL <70
DEGREE OF PROTECTION IP 21
DIMENSIONS [ L x B x H mm] 600 X 230 X 630
WEIGHT [kg] 31
PAINTING RAL 29/80081-Tiger / Austria
download specifications sheet
 
 
 

400 Hz Load Bank - Digital  120 KVA-RAB-120 D

   
120 KVA- RAB-120 D
 
model specifications
VOLTAGE [V] 115 / 200 V AC ±10 %
FREQUENCY [Hz] 400 Hz ±5 %
POWER [kW] (cos φ=1) 120 kVA
VARIABLE LOAD STEPS 0 – 120 kVA
COOLING–FORCED [m³/min] 88.20
MEASUREMENT 3 LINE DIGITAL POWER METER WITH USB OUTPUT
NORMS
STANDARDS ISO 6858, DSF 400, ARP 5015
CLASSIFICATION CE marking, DIN, VDE, IEC
ENVIRONMENT
OPERATING TEMPERATURE -10 do + 40 ºC
MAXIMUM ALTITUDE 1000 m (WITHOUT DOWNGRADING), max 2000 m
RELATIVE HUMIDITY 0% – 70% (W.O.CONDENSATION)
NOISE LEVEL <70
DEGREE OF PROTECTION IP 21
DIMENSIONS [ L x B x H mm] 600 X 230 X 630
WEIGHT [kg] 34
PAINTING RAL 29/80081-Tiger / Austria
download specifications sheet
 
 

400 Hz Load Bank - Digital  140 KVA-RAB-140 D

   
140 KVA- RAB-140 D
 
model specifications
VOLTAGE [V] 115 / 200 V AC ±10 %
FREQUENCY [Hz] 400 Hz ±5 %
POWER [kW] (cos φ=1) 140 kVA
VARIABLE LOAD STEPS 0 – 140 kVA
COOLING–FORCED [m³/min] 88.20
MEASUREMENT 3 LINE DIGITAL POWER METER WITH USB OUTPUT
NORMS
STANDARDS ISO 6858, DSF 400, ARP 5015
CLASSIFICATION CE marking, DIN, VDE, IEC
ENVIRONMENT
OPERATING TEMPERATURE -10 do + 40 ºC
MAXIMUM ALTITUDE 1000 m (WITHOUT DOWNGRADING), max 2000 m
RELATIVE HUMIDITY 0% – 70% (W.O.CONDENSATION)
NOISE LEVEL <70
DEGREE OF PROTECTION IP 21
DIMENSIONS [ L x B x H mm] 600 X 230 X 630
WEIGHT [kg] 36
PAINTING RAL 29/80081-Tiger / Austria
download specifications sheet

 

© 2012 Red Box International - 400Hz Load Banks- Analogue